2KVA ONE BATTERY INSTALLED IBADAN
INSTALLATION OF INVERTER SOLAR SYSTEM SHOULD BE BASE ON THE REQUIRED POWER CONSUMPTION.
ACHIEVERS
31/07/2025
This is a 3-phase motor control panel wiring diagram with safety and control components, using a 220V AC 3-phase power supply (60Hz). Here's a detailed explanation in English:
---
⚡ Power Supply:
Top-left indicates the system is powered by 220V AC, 3-phase, 60Hz.
Power enters through the main circuit breaker (DJG) to provide protection.
---
🔌 Main Components Inside the Control Panel (Top Section):
1. DJG (Main Breaker)
Protects the entire system from overcurrent or short circuits.
Has 3-phase input/output terminals (1L1, 3L2, 5L3 and 2T1, 4T2, 6T3).
2. DJC (Contactor for Control Power)
Supplies power to the control circuit.
Works alongside the circuit breaker and power supply module.
3. FC (Power Supply Module)
Converts 220V AC to 24V DC for logic and safety control.
+V and -V terminals indicate DC output used by other components.
4. RS (Relay Safety or Monitoring Relay)
Ensures safe operation of the control system.
Often used to monitor emergency stops or safety door switches.
5. K1 (Main Contactor)
Controls the power supply to the motor (M).
Activated when all safety conditions are met.
Has auxiliary contacts for interlocking or status feedback.
---
🚨 Control Panel Front (Bottom Section):
6. BO1 & BO2 (Emergency Stop Buttons)
Normally Closed (NC) pushbuttons labeled "EMERGENCY STOP".
Break the control circuit when pressed to stop the motor immediately.
7. BL (Start Button - Green)
Normally Open (NO) pushbutton used to start the motor.
---
⚙️ Motor (Right Side)
8. Motor (M)
3-phase electric motor controlled via the contactor.
Connected to terminals 1–6, matching a standard 3-phase wiring setup.
---
🟡 Key Wiring Paths:
Red lines: Power wires (220V AC)
Yellow/Orange lines: Control signals (24V DC)
Black/Grey lines: Neutral and earth connections
Purple lines: Motor output
---
✅ Function Summary:
1. Power flows through DJG and is split for motor and control use.
2. FC module converts AC to DC (24V) for control logic.
31/07/2025
Pop light
Click here to claim your Sponsored Listing.
Category
Contact the business
Telephone
Website
Address
14 Oremeji Street
Lagos
100241
Opening Hours
| Monday | 08:00 - 18:00 |
| Tuesday | 08:00 - 18:00 |
| Wednesday | 08:00 - 18:00 |
| Thursday | 08:00 - 18:00 |
| Friday | 08:00 - 18:00 |
| Saturday | 08:00 - 18:00 |