RISE Renewable Energy, LLC
RISE is a privately owned company looking to innovate Safety and Technical training within our industry.
04/02/2026
Weather might not be on our side, but that’s not slowing us down.
We’re excited to be receiving new equipment. Big thank you to SMA America and RST Cranes for helping make it happen.
Next up: Kodiak training coming soon, in-house at RISE Renewable Energy.
Stay tuned. 🚀
09/19/2025
We’re proud to have developed and delivered DEPCOM Power, Inc's Tech 3 training this week at RISE Renewable Energy! ⚡️
This program dives into more advanced concepts in a solar environment, giving participants the knowledge and hands-on experience needed to take their expertise to the next level.
It’s always exciting to see technicians grow in confidence and capability as they progress through these higher-level courses, strengthening both their careers and the Renewable Energy industry as a whole.
Here’s to building a stronger, smarter solar workforce for the future!
09/08/2025
☀️ Safety Monday: The Danger of False Isolation ☀️
Picture this: you’re working inside an electrical cabinet and isolate the integrated AC circuit breaker. Feels safe, right? The downstream circuit is isolated, but here’s the catch, the line side is still energized.
This creates a dangerous illusion. The busbar or connection point you’re working on may be de-energized, but energized sources are still just inches away.
And that’s where things go wrong.
Why It’s Unsafe:
❌ Dropped hardware or tools – Even a loose screw or washer can bridge into energized components, triggering a fatal arc flash.
❌ Small components slipping – Parts can fall through cracks, bulkhead passthroughs, or into adjacent compartments, making unintended contact with live conductors.
❌ False sense of security – Even when the AC breaker is in another cabinet, similar incidents have occurred because technicians assumed “breaker open” meant “cabinet safe.”
The Reality:
💡 The breaker isolates a circuit, but it does not remove the hazard.
Anytime there’s an energized source in your cabinet, your electrical boundaries still exist. This requires either:
✅ An energized work permit, or
✅ A more appropriate LOTO (Lockout/Tagout) point outside of the unit.
Bottom line: Don’t let false isolation trick you into letting your guard down.
👉 Remember: If it’s live, your boundaries stay alive.